1. Introduction to the background of vibration and noise in the power industry

1.1 Equipment safety requirements:
   
The earthquake resistance of the equipment (applicable to all major equipment) during 30 years of operation. Currently, the main earthquake resistance is evaluated by two methods: · Spectral analysis
      method:
         ·  
Standard requirements: GB 50260-2013; passed Seismic intensity and damping ratio determine the load size under different frequency excitations.
      Time history analysis method:
         Typical  
loads: sinusoidal beat waves, seismic waves, etc.
      ·Purpose of seismic analysis:
         ·  
Evaluate whether the dynamic strength of equipment under earthquake action meets the design requirements.

seismic response spectrum

sine beat wave

seismic waves

 

1.2 Noise environment requirements:

     Power equipment (mainly: transformers, reactors, capacitors, cooling fans, converter valves, etc.) will produce audible noise due to electromagnetic force during operation, and its coverage frequency range is wide: · Transformer noise:
      within 500Hz Mainly low-frequency noise;
      · Reactor noise: Mainly medium and low-frequency noise;
      · Capacitor noise: Due to its large number and the influence of harmonic currents, its noise covers a wide frequency range (low frequency to high frequency);
      · Converter valve noise: Due to the influence of IGBT, the converter valve noise covers a very wide frequency range, and the high-frequency noise is relatively high.
     Noise requirements:
         ·  
Carry out noise design for the entire substation or converter station in the early stage to effectively reduce the environmental noise of the entire station; ·
         Carry   out sound source side noise reduction design for key equipment;
         ·   Real-time monitoring of the noise of key equipment to evaluate the health of the equipment status and subsequent maintenance status.

transformer

transformer

capacitor

substation

converter valve

 

2. BOACH acoustics systematic solution for vibration and noise in the power industry:

      · Equipment structure design and strength analysis solutions
         ·  
Provide: equipment static strength, modal analysis/testing, dynamic strength analysis, earthquake resistance analysis, etc.
      · Equipment/whole-site noise analysis and noise reduction design solutions:
         ·  
Provide: sound source Side equipment/whole station noise analysis/testing, equipment/whole station noise reduction structure design and sample production, etc.
      ·Software/hardware customized solutions:
         ·  
Provide: substation/equipment noise rapid estimation system development, noise real-time monitoring system development, etc.

 

 

Capacitor Noise Analysis

Equipment/whole station noise analysis and noise reduction design

 

2.1 Equipment structure design and strength analysis solutions

      ·   Structural static strength analysis:
      ·   Structural modal analysis/testing;
      ·   Structural impact strength analysis and earthquake resistance analysis.

 

2.2 Equipment/whole station noise analysis and noise reduction design solutions:

      ·   Provide equipment noise analysis and noise reduction design services to customers;
      ·   Provide noise reduction product design, development and application for customers' actual products based on the BOACH material database (actual measurement results).

Capacitor Radiated Noise Analysis and Verification

Capacitor noise reduction product design, development and verification

Transformer Radiated Noise Analysis and Verification

Transformer noise reduction design and verification

Analysis and verification of radiated noise of converter valve

Noise analysis and noise reduction design based on materials and overall station acoustic environment

 

2.3 Software/hardware customized solutions

      · Software development:
         ·  
Development of substation/equipment noise rapid estimation system;
      · Hardware equipment research and development:
         ·  
Research and development of real-time noise monitoring and early warning system;
         ·   For details, please refer to the WeChat public account article "BOACH Acoustic Noise Monitoring and Early Warning System".

Customized software development: cases of capacitor radiation noise, converter valve radiation noise, etc.

 
We could not find any corresponding parameters, please add them to the properties table
Previous
Next

Contact us

Phone:

13611803500

Address:

Room 901, Building 1, Phase 2, Yungu Phase 2, Fengxi New Town, Xixian New District, Xixian New District, Xi'an City, Shaanxi Province

Room 307, Building 1, Harbin Institute of Technology Robot Industrial Park, No. 488 Qianjin East Road, Economic Development Zone, Kunshan City, Jiangsu Province

Site-wide search

Please enter your keywords to learn about our company

搜索
Search
Copyright Suzhou BOACH Acoustics Technology Co., Ltd. © All rights reserved
Designed By:www.300.cn SEO